Charnwood LA 45 Operations Instructions Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
THERMOSTAT
ASSEMBLY
PRE LIGHTING CHECK
Before lighting the fire check the cold setting distance of the
thermostat.
With the control knob at the maximum setting the flap should
be 18 mm from the air inlet as shown in Fig. 11. To adjust the
distance slacken the locking nut and adjust as necessary. When
set correctly re-tighten the locking nut. Ensure that the flap
opens and closes freely as the knob is turned.
Fit the side panels, hood and top grid onto the appliance.
Instructions for this are enclosed with the panel pack.
Replace any internal parts previously removed.
Before initial lighting check the following points:
1. The bottom grate bars must all be fitted and should move
freely and easily when the riddling mechanism is operated.
2. The plates round the sides and back of the grate must be in
position and sitting correctly.
3. The throat plate must be fitted in the roof of the appliance.
COMMISSIONING
FREESTANDING KIT
On completion of the installation and after allowing a suitable
period of time for the fire cement and mortar to dry out, the
fire should be lit and checked to ensure that smoke and fumes
are taken from the appliance up the chimney and emitted
safely. Also check all joints and seals.
The central heating pump should be adjusted to give the
correct water flow against the circuit resistance and the
system should be correctly balanced.
On completion of the installation and commissioning please
leave the operating instructions with the customer and advise
on the use of the fire and any controls on the system.
A freestanding kit is available. Details of dimensions and
outputs are available on request.
®
INSTALLATION INSTRUCTIONS
Thermostat Flap
Locking Nut
18mm
Fig. 11 Thermostat Setting
13